Series/Type FBC
Approval #
Size Design Pressure Uniform Structural Load*
(psf)
Water Resistance
(psf)
Impact Rating
M-85 Series: 2 11/16" Frame Depth
Single Hung FL17159.1 52" x 81" +50/-50 75 7.52 n/a
Fixed-Fixed FL17160.1 60" x 78" +50/-50 75 7.52 Large Missile Impact, Level D, Wind Zone 3 per ASTM E1886-05/E1996-05
Fixed-Fixed FL17160.2 60" x 78" +80/-80 120 12.11 n/a
Fixed FL17160.3 60" x 72" +65/-65 97.5 9.82 n/a
Fixed FL17160.4 56" x 68" +50/-50 75 7.52 Large Missile Impact, Level D, Wind Zone 3 per ASTM E1886-05/E1996-05
Horizontal Slider FL17161.1 71" x 60" +50/-50 45 4.60 n/a
M-950 Series: 3 1/4" Frame Depth
Single Hung FL17159.3 54" x 86" +80/-80 120 12.11 n/a
Single Hung FL17159.4 48" x 84" +50/-50 75 7.52 Large Missile Impact, Level D, Wind Zone 4 per ASTM E1886-05/E1996-05
Fixed FL17160.7 60" x 99" +90/-90 135 15.04 n/a
Fixed over Fixed FL17160.5 48" x 84" +50/-50 75 7.52 Large Missile Impact, Level D, Wind Zone 4 per ASTM E1886-05/E1996-05
Fixed over Fixed FL17160.6 60" x 99" +75/-75 112.5 12.12 n/a