  • Designed to meet Department of Defense (DoD) Unified Facilities Criteria (UFC) at conventional construction standoff distances
  • Qualifies for Medium Level of Protection and Minimal Glazing Hazard Rating (as tested)
  • 4 3/4” Frame depth with clip, factory applied, with the option of pre-drilled installation holes
  • Very reasonably priced engineering and blast calculations available from a nationally recognized independent 3rd party firm
  • 1” Sealed Insulated Glass
  • Wider pour and debridge polyurethane thermal break utilizing Azo-Brader™ technology
  • .062 Typical Wall Thickness – Aluminum Alloy 6063-T6

Finishes available:

  • White, Bronze (AAMA 2603)
  • 70% Fluoropolymer: White, Bronze (AAMA 2605)
  • Anodized: Clear, Bronze (AAMA 611)
    Non-standard colors are available with a minimum order

CAD Drawings
Enlarged Single-Hung Corner Section
Enlarged Fixed Corner Section
Brochure

Type Rating Structural/
Water/Air Test Size
Air Infiltration
(cfm/sq ft)
Water Resistance
(psf)
Deflection
(psf)
Structural*
(psf)
Single-Hung: Standard AW40 54W x 86H 0.10
@ 6.2 psf
8.15 40 60
Single-Hung: Optional^ AW80 60W x 99H 0.10
@ 6.2 psf
12 80 120
Single-Hung Hurricane: Standard AW40 54W x 86H 0.10
@ 6.2 psf
8.15 40 60
Horizontal Slider: Standard (Single Vent XO) AW40 72W x 62H 0.10
@ 6.27 psf
8.15 40 60
Horizontal Slider: Optional^ (Single Vent XO) CW55 72W x 62H 0.08
@ 6.27 psf
8.36 55 82.5
Fixed: Standard AW40 60W x 99H < 0.01
@ 6.2 psf
8.15 40 60
Fixed: Optional^ AW80 60W x 99H < 0.01
@ 6.2 psf
12.11 80 120
Fixed: Optional^ AW90 60W x 99H < 0.01
@ 1.57 psf
12.11 90 135
Fixed/Fixed: Standard AW40 60W x 99H < 0.01
@ 6.2 psf
8.15 40 60


^ Many window ratings can be increased by downsizing the window and determining maximum performance through testing. Contact your local Wojan Sales Representative or our office for details.

* This is an intentional overload aspect to window performance testing and should not be used in lieu of the window DP (Design Pressure) when evaluating a product for a specific project or use.

Contact us for current specification documents: 800.632.9827