3 1/4" M-950 Series Fixed Windows

Ask about our Gold Label Program for this product
- 3 1/4" Frame Depth
- Standard 1” Sealed Insulated Glass - optional 1 1/4" or 2" IGU available
- Pour and debridge polyurethane thermal break utilizing Azo-Brader™ technology
- .062 Typical Wall Thickness – Aluminum Alloy 6063-T6
- Interior and exterior accessory channels
- Hurricane Impact-Resistant model passed Large Missile Impact Testing
Finishes available:
- White, Bronze (AAMA 2603)
- 70% Fluoropolymer: White, Bronze (AAMA 2605)
- Anodized: Clear, Bronze (AAMA 611)
Non-standard colors are available with a minimum order
Accessories
CAD Drawings
Special Shapes Available
Enlarged Corner Section
M-950 Series Project Gallery
Brochure
Type | Rating | Structural/ Water/Air Test Size |
Air Infiltration (cfm/sq ft) |
Water Resistance (psf) |
Deflection (psf) |
Structural* (psf) |
---|---|---|---|---|---|---|
Standard | AW40 | 60W x 99H | < 0.01 @ 6.2 psf |
8.15 | 40 | 60 |
Optional^ | AW80 | 60W x 99H | < 0.01 @ 6.2 psf |
12.11 | 80 | 120 |
Optional^ | AW90 | 60W x 99H | < 0.01 @ 1.57 psf |
12.11 | 90 | 135 |
Fixed/Fixed: Standard | AW40 | 60W x 99H | < 0.01 @ 6.2 psf |
8.15 | 40 | 60 |
Fixed/Fixed: Optional^ | AW75 | 60W x 99H | < 0.01 @ 6.2 psf |
12.11 | 75 | 112.5 |
LMI, Fixed/Fixed: Standard FBC Approved |
DP50 | 48W x 84H | < 0.01 @ 6.2 psf |
8.15 | 50 | 75 |
^ Many window ratings can be increased by downsizing the window and determining maximum performance through testing.Contact your local Wojan Sales Representative or our office for details. | ||||||
* This is an intentional overload aspect to window performance testing and should not be used in lieu of the window DP (Design Pressure) when evaluating a product for a specific project or use. | ||||||
Contact us for current specification documents: 800.632.9827 |