2 11/16" M-85 Series Fixed Windows

is37-1316089941-45170.jpeg

Ask about our Gold Label Program for this product

  • 2 11/16” Frame Depth
  • 1” Sealed Insulated Glass
  • Pour and debridge polyurethane thermal break utilizing Azo-Brader™ technology
  • .050 Typical Wall Thickness – Aluminum Alloy 6063-T6
  • Hurricane Impact-Resistant model passed Large Missile D Zone 3 Impact Testing
  • Fixed over Louver configuration is factory stacked in one master frame, and available with all the same features and options as the standard model

Finishes available:

  • White, Bronze (AAMA 2603)
  • Anodized: Clear, Bronze (AAMA 611)

with minimum order quantity

  • 70% Fluoropolymer: White or Bronze (AAMA 2605)
  • Other non-standard colors

Accessories
CAD Drawings
Special Shapes Available
Enlarged Corner Section
Enlarged Corner Section over Louver
M-85 Series Project Gallery
Brochure

Type Rating Structural/
Water/Air
Test Size
Air Infiltration
(cfm/sq ft)
Water Resistance
(psf)
Deflection
(psf)
Structural*
(psf)
Standard CW30 60W x 72H < 0.01
@1.57 psf
4.60 30 45
Standard CW50 60W x 72H < 0.01
@ 1.6 psf
7.52 50 75
Optional^
FBC Approved
CW65 60W x 72H < 0.01
@1.57 psf
9.82 65 97.5
over Louver: Standard CW30 60W x 72H < 0.01
@ 1.57 psf
4.60 30 45
over Louver: Optional^ CW50 60W x 72H < 0.01
@ 1.6 psf
7.52 50 75
over Louver: Optional^ CW65 60W x 72H < 0.01
@ 1.57 psf
9.82 65 97.5
Fixed-Fixed: Standard CW40 60W x 78H < 0.01
@ 6.2 psf
6.06 40 60
Fixed-Fixed: Optional^ CW45 60W x 78H < 0.01
@ 6.2 psf
6.90 45 67.5
Fixed-Fixed: Optional^ C50 60W x 78H < 0.01
@ 6.2 psf
7.52 50 75
Fixed-Fixed: Optional^
FBC Approved
C80 60W x 78H < 0.01
@ 6.2 psf
12.11 80 120
LMI, Fixed: Standard
FBC Approved
DP50 56W x 68H < 0.01
@ 1.6 psf
7.52 50 75
LMI, Fixed-Fixed: Standard
FBC Approved
DP50 60W x 78H < 0.01
@ 6.2 psf
7.52 50 75
^ Many window ratings can be increased by downsizing the window and determining maximum performance through testing. Contact your local Wojan Sales Representative or our office for details.
* This is an intentional overload aspect to window performance testing and should not be used in lieu of the window DP (Design Pressure) when evaluating a product for a specific project or use.

Contact us for current specification documents: 800.632.9827